Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 25: 659-664, 1979;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sampson, E. J.
Right arrow Articles by Bayse, D. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sampson, E. J.
Right arrow Articles by Bayse, D. D.

Clinical Chemistry, Vol 25, 659-664, Copyright © 1979 by American Association for Clinical Chemistry

Relative stabilities of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase in lyophilized materials

EJ Sampson, SS McKneally, VS Whitner, CA Burtis and DD Bayse

Eight different pools of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase were prepared, to examine the effects of the following matrix variables: the matrix support material (bovine serum albumin and polyvinylpyrrolidone), endogenous pyridoxal concentration, and azide as an antimicrobial preservation. Storage temperatures of 25 and 37 degrees C were used as a rapid and convenient means of accelerating the degradation process. Activity of the enzyme was measured with and without pyridoxal in the reaction solution. We found that the mitochondrial isoenzyme was consistently more labile than the cytoplasmic isoenzyme under identical storage conditions. Both isoenzymes were more stable in matrixes containing bovine serum albumin than in those containing polyvinylpyrrolidone. No apparent difference in the stability of either isoenzyme was observed at matrix pyridoxal concentrations of 15 micromol/L and 150 micromol/L. Only the mitochondrial isoenzyme in matrixes containing bovine serum albumin and 15 micromol of pyridoxal per liter had increased activity (about 9%) when pyridoxal was added to the enzymatic reagent. The amount of activity in reconstituted specimens did not apparently change after 72 h at 4 degrees C.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1979 by the American Association for Clinical Chemistry.