Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 555-561, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowers, L. D.
Right arrow Articles by Wong, E. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowers, L. D.
Right arrow Articles by Wong, E. T.

Clinical Chemistry, Vol 26, 555-561, Copyright © 1980 by American Association for Clinical Chemistry

Kinetic serum creatinine assays. II. A critical evaluation and review

LD Bowers and ET Wong

We have evaluated the Technicon AutoAnalyzer method, the Beckman Creatinine Analyzer II, DuPont aca, Electro-Nucleonics GEMSAEC, and Instrumentation Laboratory Model 916 kinetic methods for determination of serum creatinine. These methods, which involve the Jaffe reaction, all showed a statistically significant proportional error relative to an ion-exchange pretreatment method for creatinine in 92 serum samples; the GEMSAEC method also showed a bias. The positive interference of several acid metabolites was quantitated in each of the methods. The evidence indicates that bilirubin, although associated with a negative creatinine interference, is not the sole interferent. We determined the magnitude of this interference and studied several methods for minimizing it.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
C. M. Cobbaert, H. Baadenhuijsen, and C. W. Weykamp
Prime Time for Enzymatic Creatinine Methods in Pediatrics
Clin. Chem., March 1, 2009; 55(3): 549 - 558.
[Abstract] [Full Text] [PDF]


Home page
Antimicrob. Agents Chemother.Home page
S. Sharma, T. N. C. Ramya, A. Surolia, and N. Surolia
Triclosan as a Systemic Antibacterial Agent in a Mouse Model of Acute Bacterial Challenge
Antimicrob. Agents Chemother., December 1, 2003; 47(12): 3859 - 3866.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Y. Jeremy, N. Shukla, G. D. Angelini, A. Day, I. Y.P. Wan, S. P. Talpahewa, and R. Ascione
Sustained increases of plasma homocysteine, copper, and serum ceruloplasmin after coronary artery bypass grafting
Ann. Thorac. Surg., November 1, 2002; 74(5): 1553 - 1557.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
C. R. Walsh, M. G. Larson, E. P. Leip, R. S. Vasan, and D. Levy
Serum Potassium and Risk of Cardiovascular Disease: The Framingham Heart Study
Arch Intern Med, May 13, 2002; 162(9): 1007 - 1012.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
B. F. Culleton, M. G. Larson, J. C. Evans, P. W. F. Wilson, B. J. Barrett, P. S. Parfrey, and D. Levy
Prevalence and Correlates of Elevated Serum Creatinine Levels: The Framingham Heart Study
Arch Intern Med, August 9, 1999; 159(15): 1785 - 1790.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. L. Hortin, K. Goolsby, K. A. Slickers, and H. E. Sine
Lipemia Interference with a Rate-Blanked Creatinine Method
Clin. Chem., February 1, 1997; 43(2): 408 - 410.
[Full Text]


Home page
JPEN J Parenter Enteral NutrHome page
W. W.K. Koo, L. A. Kaplan, S. K. Krug-Wispe, P. Succop, and R. Bendon
Response of Preterm Infants to Aluminum in Parenteral Nutrition
JPEN J Parenter Enteral Nutr, September 1, 1989; 13(5): 516 - 519.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1980 by the American Association for Clinical Chemistry.