Clinical Chemistry Siemens Point of Care - Urinalysis
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 871-880, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dolan, J. W.
Right arrow Articles by Snyder, L. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dolan, J. W.
Right arrow Articles by Snyder, L. R.

Clinical Chemistry, Vol 26, 871-880, Copyright © 1980 by American Association for Clinical Chemistry

On-line liquid-chromatographic analysis for drugs in serum with the Technicon "FAST-LC" system: performance data for theophylline and for four commonly used anticonvulsants and their metabolites

JW Dolan, S van der Wal, SJ Bannister and LR Snyder

We describe a new instrument for use in assay of therpeutic drugs in serum by "high-performance" liquid chromatography, the "FAST-LC" system (Technicon). Serum samples are aspirated directly into the unit, extracted with solvent, and the evaporated and redissolved extract is injected onto a chromatographic column. We illustrate the performance of the system by assays in serum for theophylline and four anticonvulsants (primidone, phenobarbital, phenytoin, and carbamazepine) plus two of their active metabolites (phenylethylmalonamide and carbamazepine epoxide). For theophylline, final chromatograms are monitored at 270 nm, at analysis rates of 10/h. Concentration and absorbance are linearly related from 0 to 130 mg of theophylline per liter. For the anticonvulsants, chromatograms are monitored at 200 nm, at analysis rates of 7.5/h. The six individual determinations are each linear beyond the therapeutic range. For both drug panels, day-to-day CV's were 4 to 6%. Results correlate well with those by enzyme immunoassay. A total sample volume of 150 microL is required.


The following articles in journals at HighWire Press have cited this article:


Home page
ScienceHome page
R. Elin
Instrumentation in clinical chemistry
Science, October 17, 1980; 210(4467): 286 - 289.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1980 by the American Association for Clinical Chemistry.