Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 26: 1357-1359, 1980;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Virella, G.
Right arrow Articles by Colwell, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Virella, G.
Right arrow Articles by Colwell, J.

Clinical Chemistry, Vol 26, 1357-1359, Copyright © 1980 by American Association for Clinical Chemistry

Simplified method for detecting anti-insulin antibodies and insulin- anti-insulin immune complexes

G Virella, D Russell, M Laimins and J Colwell

A simplified approach for estimating free and total anti-insulin antibodies and soluble insulin-anti-insulin immune complexes in serum has been developed and evaluated. For determination of free anti- insulin antibodies, a binding ratio for 125I-labeled insulin at fivefold serum dilution is calculated; the binding ratios obtained are reproducible (run-to-run coefficient of variation, 7.3%) and correlate well with titration of anti-insulin antibodies by other techniques (correlation coefficient, 0.9327). Total anti-insulin antibody concentrations are determined by calculating the [125I]insulin binding ratio for a sample previously acidified, adsorbed with acid dextran- coated charcoal, and neutralized. The difference in binding ratios between two aliquots of the same serum, one diluted 10-fold without manipulation and the second studied at an identical dilution after acidification and removal of free insulin, is taken as an index of the presence of soluble insulin-anti-insulin immune complexes. Because the tests can be performed at a single dilution, both time and materials are conserved without apparent loss of discrimination between sera with high antibody titers and high concentrations of insulin-anti-insulin immune complexes and sera with negative titers or low concentrations.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1980 by the American Association for Clinical Chemistry.