Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 116-123, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Warnick, G. R.
Right arrow Articles by Albers, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Warnick, G. R.
Right arrow Articles by Albers, J. J.

Clinical Chemistry, Vol 27, 116-123, Copyright © 1981 by American Association for Clinical Chemistry

Evaluation of quality-control materials for high-density-lipoprotein cholesterol quantitation

GR Warnick, C Mayfield and JJ Albers

Commercial quality-control materials and frozen plasma and serum pools were evaluated for high-density lipoprotein (HDL) cholesterol quantitation by the heparin-Mn2+ and phosphotungstate-Mg2+ precipitation methods and by ultracentrifugal and electrophoretic methods. We evaluated among-day precision; inter-method differences in HDL cholesterol quantitation; lipid composition and electrophoretic mobility of th lipoprotein density fractions; and the effects of modifications in reagent concentration and temperature. Frozen plasma pools (in-house) and frozen serum pools (prepared by the Center for Disease Control) were determined to be suitable HDL controls. Also, a commercial lyophilized serum free of very-low-density lipoprotein (VLDL) to which VLDL is added in a diluent solution (Analytical Control) also appeared suitable as an HDL control material. Conventional lyophilized pools (Lyphochek Elevated, Monitrol I, Ortho Normal, Precilip) were less suitable as control materials because of poor between-day precision for one or both of the precipitation methods and, in some cases, because of large absolute differences observed between the HDL methods. A serum pool stabilized with ethylene glycol (Beckman Level I) was the least as appropriate as an HDL control material. Other lyophilized pools--Lipid Fraction Control (Hyland) prepared by a modified lyophilization process and Lipidophor (Immuno Diagnostika) prepared by lyophilization with a stabilizing agent-- appear promising.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.