Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 166-168, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jung, D.
Right arrow Articles by Perrier, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jung, D.
Right arrow Articles by Perrier, D.

Clinical Chemistry, Vol 27, 166-168, Copyright © 1981 by American Association for Clinical Chemistry

The "ultra-free" ultrafiltration technique compared with equilibrium dialysis for determination of unbound thiopental concentrations in serum

D Jung, M Mayersohn and D Perrier

We compare a new ultrafiltration technique, involving a unique Millipore membrane, with the classical method of equilibrium dialysis for determining the fraction of thiopental not bound to serum proteins. This fraction, as determined by equilibrium dialysis at 37 degrees C, ranged between 12 and 16% for total concentrations at 50 microgram/L to 10 mg/L of serum. In contrast, ultrafiltration at 37 degrees C yielded a 49% higher value for unbound thiopental: 26.3 (SD 2.6)%. Determined at room temperature (24 degrees C), there was no statistically significant difference for results by the two methods: 14.2 and 15.9%, respectively. The discrepancy between results at 37 degrees C may partly be explained by serum proteins penetrating the Ultra-Free filter. For the routine clinical measurement of unbound drug concentrations, the ultrafiltration membrane at room temperature appears to be sufficiently accurate and less time-consuming than equilibrium dialysis.


The following articles in journals at HighWire Press have cited this article:


Home page
Arch NeurolHome page
H. J. DeMonaco
Variability of Phenytoin Protein Binding in Epilepsy-Reply
Arch Neurol, April 1, 1984; 41(4): 363 - 363.
[Abstract] [PDF]


Home page
Arch NeurolHome page
H. J. DeMonaco and L. M. Lawless
Variability of Phenytoin Protein Binding in Epileptic Patients
Arch Neurol, August 1, 1983; 40(8): 481 - 483.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.