Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 35-38, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ono, T.
Right arrow Articles by Hayami, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ono, T.
Right arrow Articles by Hayami, K.

Clinical Chemistry, Vol 27, 35-38, Copyright © 1981 by American Association for Clinical Chemistry

Serum-constituents analyses: effect of duration and temperature of storage of clotted blood

T Ono, K Kitaguchi, M Takehara, M Shiiba and K Hayami

We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, cholinesterase (EC 3.1.1.8), alkaline phosphatase (EC 3.1.3.1), leucine aminopeptidase (EC 3.4.11.1), amylase (EC 3.2.1.2), total cholesterol, triglycerides, beta- lipoprotein, serum urea nitrogen, creatinine, uric acid, and gamma- glutamyltransferase (EC 2.3.2.2) were not influenced by storage at 4, 24, or 30 degrees C for as long as 48 h. Negligible differences were seen for potassium in sera in contact with cells as long as 24 h at 23 degrees C and for inorganic phosphorus after 48 h at 4 degrees C. However, at 4 degrees C we noted an increase at 8 h, a slight decrease at 30 degrees C. Statistically significant changes were seen for total protein and calcium after 48 h at 30 degrees C; for aspartate aminotransferase (EC 2.6.1.1), and alanine aminotransferase (EC 2.6.1.2), between 8 and 24 h at 23 degrees C and as soon as 6 h at 30 degrees C; for lactate dehydrogenase (EC 1.1.1.27) after 8 h at 30 degrees C and between 8 and 24 h at 23 degrees C; for glucose at 24, 4, or 2 h of storage at 4, 23, or 30 degrees C, respectively; for inorganic phosphorus after 48 h at 23 degrees C or 8 h at 30 degrees C; for potassium after 4 h at 4 degrees C or 24 h at 30 degrees C; and for sodium after 48 h at 4 degrees C or 6 h at 23 or 30 degrees C.


The following articles in journals at HighWire Press have cited this article:


Home page
Ann Clin BiochemHome page
M. Tanner, N. Kent, B. Smith, S. Fletcher, and M. Lewer
Stability of common biochemical analytes in serum gel tubes subjected to various storage temperatures and times pre-centrifugation
Ann Clin Biochem, July 1, 2008; 45(4): 375 - 379.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M.-A. von Mach, L. S. Weilemann, and P. von Landenberg
Pseudocholinesterase Activity in Organophosphate Poisoning after Storage of Unseparated Blood Samples at Room Temperature for 3 Weeks
Clin. Chem., October 1, 2005; 51(10): 1907 - 1908.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
E. J. Giltay, J. M. Geleijnse, E. G. Schouten, M. B. Katan, and D. Kromhout
High Stability of Markers of Cardiovascular Risk in Blood Samples
Clin. Chem., April 1, 2003; 49(4): 652 - 655.
[Full Text] [PDF]


Home page
Int J EpidemiolHome page
S. Clark, L. D Youngman, A. Palmer, S. Parish, R. Peto, and R. Collins
Stability of plasma analytes after delayed separation of whole blood: implications for epidemiological studies
Int. J. Epidemiol., February 1, 2003; 32(1): 125 - 130.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
B. L. Boyanton Jr and K. E. Blick
Stability Studies of Twenty-Four Analytes in Human Plasma and Serum
Clin. Chem., December 1, 2002; 48(12): 2242 - 2247.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. R. Dufour, J. A. Lott, F. S. Nolte, D. R. Gretch, R. S. Koff, and L. B. Seeff
Diagnosis and Monitoring of Hepatic Injury. I. Performance Characteristics of Laboratory Tests
Clin. Chem., December 1, 2000; 46(12): 2027 - 2049.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
D. J. Zhang, R. K. Elswick, W. G. Miller, and J. L. Bailey
Effect of serum-clot contact time on clinical chemistry laboratory results
Clin. Chem., June 1, 1998; 44(6): 1325 - 1333.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.