Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 68-72, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pleban, P. A.
Right arrow Articles by Pearson, K. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pleban, P. A.
Right arrow Articles by Pearson, K. H.

Clinical Chemistry, Vol 27, 68-72, Copyright © 1981 by American Association for Clinical Chemistry

Polarized Zeeman-effect flameless atomic absorption spectrometry of cadmium, copper, lead, and manganese in human kidney cortex

PA Pleban, J Kerkay and KH Pearson

We used polarized Zeeman-effect flameless atomic absorption spectroscopy to quantitatively measure cadmium, copper, lead, and manganese in a nitric acid digest of lyophilized human kidney cortex. Within-run coefficients of variation for cadmium, copper, lead, and manganese, 15.3, 177.2, 84.2, and 56.3 microgram/L, respectively, were 4.1, 6.3, 3.7, and 5.6%, respectively. Between-run coefficients of variation were 6.9, 5.5, 5.9, and 6.3%, respectively, for cadmium, copper, lead, and manganese concentrations of 135.1, 12.8, 2.72, and 3.80 microgram/g, respectively. For cadmium, copper, lead, and manganese digest concentrations (mean +/- SE) of 15.3 +/- 0.6, 41.4 +/- 2.6, 9.4 +/- 0.6, and 20.9 +/- 0.4 microgram/L, respectively, the detection limits were 5.2 microgram/L for copper, 1.2 microgram/L for both cadmium and lead, and 0.8 microgram/L for manganese. Assays were linear to 75 microgram/L for cadmium, 100 microgram/L for manganese, and 200 microgram/L for copper and lead. Average analytical recoveries for the four metals ranged between 95 and 101%. Because these metals were quantitated in the same digest of kidney cortex, the values for each digest gave a trace-metal profile for each autopsy specimen.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.