Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1983-1987, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamatodani, A.
Right arrow Articles by Wada, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamatodani, A.
Right arrow Articles by Wada, H.

Clinical Chemistry, Vol 27, 1983-1987, Copyright © 1981 by American Association for Clinical Chemistry

Automated analysis for plasma epinephrine and norepinephrine by liquid chromatography, including a sample cleanup procedure

A Yamatodani and H Wada

We describe a fully automated method of analysis for plasma epinephrine and norepinephrine by use of a two-column system of "high-performance" liquid chromatography. Catecholamines in deproteinized plasma are purified on the first (preparation) column, then transferred automatically to the second (analytical) column in which epinephrine and norepinephrine are resolved. These compounds are then determined fluorometrically with a continuous-flow reaction system by the trihydroxyindole method. The minimum sensitivity of the method is 0.02 and 0.04 pmol for epinephrine and norepinephrine, respectively. One assay can be completed in 30 min, and greater than 1 mL of plasma is required for the procedure. The within-run CV in the chromatographic determination of pooled plasma was greater than 3%, and the analytical overall recovery of the two compounds was 95%. The concentrations in plasma of medical students at rest were 0.32 (SE 0.06) nmol/L for epinephrine and 0.98 (SE 0.08) nmol/L for norepinephrine.


The following articles in journals at HighWire Press have cited this article:


Home page
J. Appl. Physiol.Home page
I. Kuwahira, U. Kamiya, T. Iwamoto, Y. Moue, T. Urano, Y. Ohta, and N. C. Gonzalez
Splenic contraction-induced reversible increase in hemoglobin concentration in intermittent hypoxia
J Appl Physiol, January 1, 1999; 86(1): 181 - 187.
[Abstract] [Full Text] [PDF]


Home page
HypertensionHome page
T. Yamakawa, S.-i. Tanaka, K. Tamura, F. Isoda, K. Ukawa, Y. Yamakura, Y. Takanashi, Y. Kiuchi, S. Umemura, M. Ishii, et al.
Wistar Fatty Rat Is Obese and Spontaneously Hypertensive
Hypertension, January 1, 1995; 25(1): 146 - 150.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.