Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 286-292, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fell, A. F.
Right arrow Articles by Stewart, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fell, A. F.
Right arrow Articles by Stewart, M. J.

Clinical Chemistry, Vol 27, 286-292, Copyright © 1981 by American Association for Clinical Chemistry

Analysis for paraquat by second- and fourth-derivative spectroscopy

AF Fell, DR Jarvie and MJ Stewart

We describe simple, precise methods, based on second and fourth- derivative spectroscopy, of analysis for paraquat in serum, plasma, or dialysis fluid. Plasma paraquat, after ion-pair extraction and dithionite reduction, yields a sharp, stable absorption peak at 396 nm. Derivative spectroscopy confers enhanced sensitivity (detection limit, 5 microgram/L) and improved rejection of spectroscopic interference by diquat, hemolysis, bilirubin, or lipemia. Derivative peak amplitudes are linearly related to paraquat dichloride concentration from 10 to 1000 microgram/L in plasma, and the methods are precise (CV 2.7-5.2% for 50 microgram/L concentration) and accurate. Results of derivative assays for 18 cases of paraquat poisoning correlate well with those by radioimmunoassay (r = 0.999). Derivative spectroscopy enables monitoring of paraquat concentrations in the plasma of poisoned patients during treatment by hemoperfusion or hemodialysis. A rapid assay developed for dialysis fluid (detection limit, 2 microgram/L) permits the efficacy of hemodialysis to be routinely assessed.


The following articles in journals at HighWire Press have cited this article:


Home page
Hum Exp ToxicolHome page
R.A. Braithwaite
Emergency Analysis of Paraquat in Biological Fluids
Human and Experimental Toxicology, January 1, 1987; 6(1): 83 - 86.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.