Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 303-307, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Solberg, H. E.
Right arrow Articles by Stromme, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Solberg, H. E.
Right arrow Articles by Stromme, J. H.

Clinical Chemistry, Vol 27, 303-307, Copyright © 1981 by American Association for Clinical Chemistry

gamma-Glutamyltransferase in human serum: an analysis of kinetic models

HE Solberg, L Theodorsen and JH Stromme

The purpose of the study was to elucidate details of the kinetic model for gamma-glutamyltransferase when assayed with gamma-glutamyl-3- carboxy-4-nitroanilide and glycylglycine as substrates. Data from several sets of initial velocity measurements were fitted by nonlinear regression to a set of different kinetic models. gamma- Glutamyltransferase acts by a "ping-pong bi-bi" mechanism. A model encompassing transfer and autotransfer, competitive inhibition by the acceptor substrate, and no inhibition by the donor substrate gives the best fit to the experimental data. Effects of spectrophotometric nonlinearity may simulate noncompetitive inhibition by the donor substrate. The nonlinearity is dependent on the absorption of the incubation mixture and therefore is related to the concentration of the donor substrate and the wavelength (405-412 nm) used to monitor the reaction. With decreasing pH the autotransfer fraction decreases and the binding of the donor substrate to the acceptor site increases, simulating an increased competitive inhibition by the donor substrate. These results are of importance when elaborating optimum assay conditions for gamma-glutamyltransferase in serum.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.