Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 486-490, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gross, T. L.
Right arrow Articles by Sokol, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gross, T. L.
Right arrow Articles by Sokol, R. J.

Clinical Chemistry, Vol 27, 486-490, Copyright © 1981 by American Association for Clinical Chemistry

Clinical laboratory determination of phosphatidylglycerol: one- and two- dimensional chromatography compared

TL Gross, MV Wilson, PM Kuhnert and RJ Sokol

Reportedly, determination of several phospholipids in amniotic fluid, including phosphatidylglycerol and phosphatidylinositol, in addition to lecithin and sphingomyelin improves prediction of neonatal pulmonary function. In this study, we evaluated a two-dimensional technique for separating and measuring these phospholipids and compared it with a simpler one-dimensional procedure. The two-dimensional technique was adapted to readily available commercial plates, and a preheating step was introduced to avoid shattering of the plates during charring. The Rf values, reproducibility of each technique, and the correlation between them were examined. Even though the one-dimensional technique is faster and less expensive, we recommend the two-dimensional method for clinical use because of better precision (CV for phosphatidylglycerol 15% vs 21%) and clearer results when relatively little phosphatidylglycerol is present. The one-dimensional procedure is unreliable when blood or meconium are present. In addition, interfering compounds co-migrate with phosphatidylglycerol, phosphatidylethanolamine, and phosphatidylserine in the one-dimensional technique. Before any one-dimensional lipid separation is adopted for clinical use, it should be critically compared to the two-dimensional procedure.