Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 569-573, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shephard, M. D.
Right arrow Articles by Fraser, C. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shephard, M. D.
Right arrow Articles by Fraser, C. G.

Clinical Chemistry, Vol 27, 569-573, Copyright © 1981 by American Association for Clinical Chemistry

Short- and long-term biological variation in analytes in urine of apparently healthy individuals

MD Shephard, LA Penberthy and CG Fraser

Intra-individual, interindividual, and analytical components of variation for each of 10 urine analytes were estimated from results obtained on analysis of urine specimens from 10 apparently healthy young men. In spot urines, urea and osmolality showed strong individuality, but intra-individual variances were larger than interindividual variances for sodium, urate, phosphate, and glucose. Urea and osmolality displayed strong individuality in daily urines, whereas sodium (when results were expressed in output terms), urate, potassium, and total protein (when results were expressed in concentration units) had intra-individual variances larger than interindividual variances. In monthly urines, calcium and glucose, in concentration terms, and phosphate, in output terms, exhibited strongest individuality. Analytical variance was a significant percentage of the total variance for total protein and glucose; the analytical methods we used for these analytes were probably unsatisfactory. A series of analytical goals for imprecision, based on biological variation, were derived. Although these goals may not be applicable in all clinical situations, they represent the beginning of a data base in the literature.


The following articles in journals at HighWire Press have cited this article:


Home page
ANN OCCUP HYGHome page
A. H. GARDE, A. M. HANSEN, J. KRISTIANSEN, and L. E. KNUDSEN
Comparison of Uncertainties Related to Standardization of Urine Samples with Volume and Creatinine Concentration
Ann. Hyg., March 1, 2004; 48(2): 171 - 179.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
H. W. Vesper, L. M. Demers, R. Eastell, P. Garnero, M. Kleerekoper, S. P. Robins, A. K. Srivastava, G. R. Warnick, N. B. Watts, and G. L. Myers
Assessment and Recommendations on Factors Contributing to Preanalytical Variability of Urinary Pyridinoline and Deoxypyridinoline
Clin. Chem., February 1, 2002; 48(2): 220 - 235.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.