Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 759-761, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nexo, E.
Right arrow Articles by Olesen, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nexo, E.
Right arrow Articles by Olesen, H.

Clinical Chemistry, Vol 27, 759-761, Copyright © 1981 by American Association for Clinical Chemistry

Volume of blood removed for analytical purposes during hospitalization of low-birthweight infants

E Nexo, NC Christensen and H Olesen

Iatrogenic hazards may be induced by blood sampling in very-low- birthweight neonates. We report the number and types of analyses performed on 20 neonates with a birthweight below 1500 g during their first four weeks of hospitalization. Blood was sampled one to 13 times per infant per day on 382 of the 435 total days of hospitalization. The average blood loss was 7 to 51 mL per kilogram of body weight per four weeks--that is, from 5 to 45% of the calculated total blood volume. Of the blood removed, about 25% was in excess of the need for analytical procedures. Of the analyses, 40% were for acid-base, sodium, and potassium analyses--analyses for which transcutaneous methodology has been or is being developed. We conclude that because of the risks for low-birthweight neonates, procedures for blood sampling and analysis should periodically be reviewed, so as to minimize the number of samplings and the amount of blood removed.


The following articles in journals at HighWire Press have cited this article:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
E F Bell
When to transfuse preterm babies
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2008; 93(6): F469 - F473.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
T. G. Connell, M. Rele, D. Cowley, J. P. Buttery, and N. Curtis
How Reliable Is a Negative Blood Culture Result? Volume of Blood Submitted for Culture in Routine Practice in a Children's Hospital
Pediatrics, May 1, 2007; 119(5): 891 - 896.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
H Vertanen, V Fellman, M Brommels, and L Viinikka
An automatic incision device for obtaining blood samples from the heels of preterm infants causes less damage than a conventional manual lancet
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2001; 84(1): 53F - 55.
[Abstract] [Full Text]


Home page
Arch Pediatr Adolesc MedHome page
J. P. Blank, T. G. Sheagren, J. Vajaria, H. H. Mangurten, R. S. Benawra, and B. L. Puppala
The Role of RBC Transfusion in the Premature Infant
Arch Pediatr Adolesc Med, September 1, 1984; 138(9): 831 - 833.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.