Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 875-878, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Meites, S.
Right arrow Articles by Thompson, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Meites, S.
Right arrow Articles by Thompson, C.

Clinical Chemistry, Vol 27, 875-878, Copyright © 1981 by American Association for Clinical Chemistry

Studies on the quality of specimens obtained by skin puncture of children 1. Tendency to hemolysis, and hemoglobin and tissue fluid as contaminants

S Meites, SS Lin and C Thompson

When preferred skin-puncture and blood-collecting techniques were used, the mean artifactually produced hemoglobin in 417 samples of plasma from pediatric patients was 260 mg/L. Highest values occurred exclusively in newborns, 0 to 13 days old (n = 176; mean, 390 mg/L), one-third of whom were premature. The highest value was 1470 mg/L. Only 3% of the samples exceeded 1000 mg/L. After 13 days, technically produced hemolysis is about the same as that for adult plasma (less than 200 mg/L). When skin-puncture and blood-collecting techniques are faulty--e.g., from excessive squeezing at the puncture site--plasma K and hemoglobin may be increased in the newborn to 13-day-old infant, and occasionally in older subjects. By determining plasma hemoglobin, K, blood hemoglobin, and hematocrit the contribution of "tissue fluid" is readily calculated. With excessive squeezing at the sampling site, tissue fluid sometimes contaminates plasma with hemoglobin and K, particularly in the youngest group. Values for alanine and aspartate aminotransferases, lactate dehydrogenase, inorganic P, and Na were little altered, even with squeezing, a fact particularly surprising for the enzymes, which are known to be present in markedly higher concentrations in erythrocytes and other tissues. Our data validate the Elson--Ivor--Gochman method (Am. J. Clin. Pathol. 69: 354-355, 1978) for quantitation of hemoglobin in plasma.


The following articles in journals at HighWire Press have cited this article:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
Z Hassan and M Shah
Scald injury from the Guthrie test: should the heel be warmed?
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2005; 90(6): F533 - F534.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
D. Schwartz, N. R. Connelly, P. Manikantan, and J. H. Nichols
Hyperkalemia and Pyloric Stenosis
Anesth. Analg., August 1, 2003; 97(2): 355 - 357.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
H Vertanen, V Fellman, M Brommels, and L Viinikka
An automatic incision device for obtaining blood samples from the heels of preterm infants causes less damage than a conventional manual lancet
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2001; 84(1): 53F - 55.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
S. Meites
History of Clinical Chemistry in a Children's Hospital (1914-1964)
Clin. Chem., July 1, 2000; 46(7): 1009 - 1013.
[Abstract] [Full Text] [PDF]


Home page
Arch Pediatr Adolesc MedHome page
B. Paes, M. Janes, P. Vegh, F. LaDuca, and M. Andrew
A Comparative Study of Heel-stick Devices for Infant Blood Collection
Arch Pediatr Adolesc Med, March 1, 1993; 147(3): 346 - 348.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.