Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1227-1232, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kessner, A.
Right arrow Articles by Bowers, G. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kessner, A.
Right arrow Articles by Bowers, G. N., Jr

Clinical Chemistry, Vol 27, 1227-1232, Copyright © 1981 by American Association for Clinical Chemistry

Response monitoring and action limits: use of ADC numbers in understanding the operational characteristics of the Beckman ASTRA chemistry system

A Kessner, RW Burnett and GN Bowers Jr

The Beckman ASTRA is a microprocessor-controlled multichannel chemistry analyzer. The output of each module is available to the operator as analog-to-digital conversion (ADC) numbers, which we record during each calibration (Response Monitoring). After so studying three instruments for a total of 33 months, we have established limits for Calibrator ADC numbers that indicate possible operator action (Action Limits). These Action Limits are tighter than the microprocessor's programmed limits, and alert the operator to short- and long-term drift. These tighter limits warn of (a) impending failure of the instrument to calibrate or (b) possible inaccuracies in results for patients. We have instituted changes in preventive maintenance based on our studies of each module's operational characteristics, and have replaced electrodes that failed to meet our Response Monitoring specifications. Response Monitoring and Action Limits based upon ADC numbers have significantly enhanced our understanding of the ASTRA system and thus improved its operational efficiency and analytical reliability. Estimates of precision and accuracy (true value) were satisfactory in comparison to our prior single-channel continuous-flow and flame photometry analytical measurement systems.