Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1372-1377, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowers, G. N.
Right arrow Articles by Ewen, L. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowers, G. N., Jr
Right arrow Articles by Ewen, L. M.

Clinical Chemistry, Vol 27, 1372-1377, Copyright © 1981 by American Association for Clinical Chemistry

Spectrophotometric and liquid-chromatographic studies of thymolphthalein monophosphate. Specifications for high-quality substrate for the measurement of prostatic acid phosphatase activity

GN Bowers Jr, M Onoroski, RS Schifreen, LR Brown, RE Klem and LM Ewen

Fourteen lots of thymolphthalein monophosphate (TMP), disodium salt, obtained from 10 commercial suppliers were compared spectrophotometrically at 445 and 595 nm, liquid-chromatographically with monitoring at 254 nm, and enzymically by measurements of activity of prostatic acid phosphatase in human serum. Eight lots were classified as "unacceptable," six as "acceptable." Spectrophotometric testing revealed four lots with excessive thymolphthalein and three lots with grossly deficient amounts of TMP. In general, the chromatographic results paralleled those obtained by spectrophotometry, and both results correlated well with enzymic activity. Changing water content in this hygroscopic salt was a major problem, which resulted in great uncertainty as to the formula weight and therefore as to the moles of TMP actually taken. From these studies, specifications for high-quality TMP were determined. The critical importance of simultaneous enzymic activity measurements in comparisons with other "acceptable" lots in defining an adequate TMP substrate is stressed. Use of these specifications for selecting TMP for acid phosphatase activity measurements should improve intra- and inter-laboratory analytical performance.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1981 by the American Association for Clinical Chemistry.