Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 27: 1558-1568, 1981;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rich, E. S.
Right arrow Articles by Wampler, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rich, E. S., Jr
Right arrow Articles by Wampler, J. E.

Clinical Chemistry, Vol 27, 1558-1568, Copyright © 1981 by American Association for Clinical Chemistry

A flexible, computer-controlled video microscope capable of quantitative spatial, temporal, and spectral measurements

ES Rich Jr and JE Wampler

A video microscope system has been constructed and tested that incorporates computer-controlled video cameras for high-resolution and low-light microscopy. The low-light camera system involves a dual microchannel plate-image intensifier capable of photon gain as high as 500 000 and a gated silicone-intensified target vidicon to achieve usable photon sensitivity with a noise equivalent signal of only 2 photons (500 nm) per pixel per second. We have compared the limitations and capabilities of this camera system with those of a high-resolution video camera and conventional photomicroscopy. Uses of the low-light camera coupled to a computer system include image acquisition of weak- light images from self-luminous specimens, fluorescence microscopy with weak exciting light, kinetic resolution of calcium-mediated events as monitored by the calcium-sensitive bioluminescence of aequorin, and spatially resolved spectroscopic measurements. Flexible use of this system in these various applications is possible because it allows operation with illumination intensities over a dynamic range of 100 000:1.