Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 129-133, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drop, L. J.
Right arrow Articles by Misiano, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drop, L. J.
Right arrow Articles by Misiano, D. R.

Clinical Chemistry, Vol 28, 129-133, Copyright © 1982 by American Association for Clinical Chemistry

Comparative evaluation of two calcium ion-selective electrode systems, and their utility for monitoring steady-state changes in [Ca2+]

LJ Drop, LN Tochka and DR Misiano

We compared ionized calcium concentrations ([Ca2+]) as measured with two ionized-calcium analyzers: the NOVA 2 and the Orion SS-20. Samples were obtained from 43 human volunteers, 213 patients, and five dogs (106 samples). In the [Ca2+] range of 0.85 to 1.8 mmol/L, [Ca2+] measurements in whole blood with the NOVA 2 consistently exceeded those measured with the Orion SS-20. However, in the normal range, this difference appeared to be smaller when we compared values for plasma or serum, and was absent over the entire range when we compared aqueous solutions. The normal human [Ca2+] in whole blood as measured with the NOVA 2 is 1.22 +/- 0.01 mmol/L (mean +/- SEM) and that with the Orion SS-20 is 1.12 +/- 0.01 mmol/L (p less than 0.0001 by paired t-test); the 95% confidence intervals were from 1.14 to 1.30 and from 1.02 to 1.22 mmol/L, respectively. Using dogs, we also tested the usefulness of the ionized-calcium electrode for monitoring [Ca2+] during infusion of either citrate or calcium chloride solutions, to produce steady-state alterations in [Ca2+] equilibrium. Frequent successive [Ca2+] measurements were essential to appropriately adjust the infusion rates of these solutions to achieve steady-state [Ca2+].





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.