Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 2139-2143, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leung, F. Y.
Right arrow Articles by Henderson, A. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leung, F. Y.
Right arrow Articles by Henderson, A. R.

Clinical Chemistry, Vol 28, 2139-2143, Copyright © 1982 by American Association for Clinical Chemistry

Improved determination of aluminum in serum and urine with use of a stabilized temperature platform furnace

FY Leung and AR Henderson

This method for determining aluminum in serum and urine is essentially free from matrix interference and gives a linear response with concentration to at least 500 micrograms/l. Use of a stabilized temperature platform (L'vov platform, Perkin-Elmer Corp.) to approach a "steady-state" temperature, addition of matrix modifiers [especially Mg(NO3)2], and the use of peak area integration all helped substantially diminish spectral interference. With the platform furnace, serum protein concentrations as great as 260 g/L did not interfere with the determination of Al. The within- and between-assay precision (CV) was less than or equal to 3.5% and less than or equal to 7.4%, respectively. Analytical recovery of Al added to serum ranged between 95 and 101% throughout the linear calibration range (to 500 micrograms/L), either when measured directly from the standard curve or by the method of standard additions. The reference interval for Al in 28 healthy subjects was 2-14 micrograms/L (mean 6.5, SD 4.1 micrograms/L), and for 130 patients on hemodialysis, 20-550 micrograms/L (mean 87.5, SD 62.5 micrograms/L).





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.