|
|
||||||||
Clinical Chemistry, Vol 28, 356-360, Copyright © 1982 by American Association for Clinical Chemistry
LA McElderry, IF Tarbit and AJ Cassells-Smith
Six assays for protein in urine were compared for linearity, ease of standardization, precision, comparability of assay values, technical ease of assay, and current cost. The assays investigated were three dye- binding techniques, a recent turbidimetric technique, the trichloroacetic acid--biuret reaction, and a tannic acid protein precipitation reaction with ferric chloride. All assays suffered from standardization problems, although the biuret method showed the best analytical recovery of albumin and gamma-globulin. The tannic acid/ferric chloride method is dependent on sample pH. The turbidimetric assay exhibited the greatest imprecision; i.e., CVs were 19.5% at a protein concentration of 0.13 g/L and 6.0% at a protein concentration of 1.3 g/L. On the basis of all the factors assessed, we conclude that the Pesce/Strande Ponceau-S and the Bio-Rad Coomassie Brilliant Blue dye-binding techniques offer certain advantages over the other assays studied.
The following articles in journals at HighWire Press have cited this article:
![]() |
A. Leanos-Miranda, J. Marquez-Acosta, F. Romero-Arauz, G. M. Cardenas-Mondragon, R. Rivera-Leanos, I. Isordia-Salas, and A. Ulloa-Aguirre Protein:Creatinine Ratio in Random Urine Samples Is a Reliable Marker of Increased 24-Hour Protein Excretion in Hospitalized Women with Hypertensive Disorders of Pregnancy Clin. Chem., September 1, 2007; 53(9): 1623 - 1628. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Barratt MB ChB (Ho and P. Topham MB ChB MD Urine proteomics: the present and future of measuring urinary protein components in disease Can. Med. Assoc. J., August 14, 2007; 177(4): 361 - 368. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Luo, M. Chen, Q. Wen, M. Zhao, B. Zhang, X. Li, F. Wang, Q. Huang, C. Yao, T. Jiang, et al. Rapid and Simultaneous Quantification of 4 Urinary Proteins by Piezoelectric Quartz Crystal Microbalance Immunosensor Array Clin. Chem., December 1, 2006; 52(12): 2273 - 2280. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. R. Tate, D. Gill, R. Cobcroft, and P. E. Hickman Practical Considerations for the Measurement of Free Light Chains in Serum Clin. Chem., August 1, 2003; 49(8): 1252 - 1257. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Marshall and K. M. Williams Total Protein Determination in Urine: Elimination of a Differential Response between the Coomassie Blue and Pyrogallol Red Protein Dye-binding Assays Clin. Chem., March 1, 2000; 46(3): 392 - 398. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |