Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 683-686, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Katan, M. B.
Right arrow Articles by Schouten, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Katan, M. B.
Right arrow Articles by Schouten, F. J.

Clinical Chemistry, Vol 28, 683-686, Copyright © 1982 by American Association for Clinical Chemistry

Standardization of serum cholesterol assays by use of serum calibrators and direct addition of Liebermann-Burchard reagent

MB Katan, F van der Haar, D Kromhout and FJ Schouten

Serum cholesterol concentrations of subjects in epidemiological studies were measured after direct addition of Liebermann-Burchard reagent; results were calibrated with human serum pools assayed according to Abell et al. (J. Biol. Chem. 195:357-366, 1952). Accuracy and precision were monitored for six years by analysis of internal-control pools and blind external-control pools. For various internal-control pools, the imprecision (CV) of the long-term averages of run means ranged from 0.5 to 0.9%. The within-run CV for internal control and patients' sera was about 1%. For blind control sera with different concentrations (provided by the Centers for Disease Control, Atlanta, GA, over the same period), the average difference per three-month period between the values found and the target values was usually between -0.5% and +0.7% for medium-concentration pools and between -2% and +2% for low- and high-concentration pools (extreme values: -2.4% and +2.5%). The CV per three-month period ranged from 0.6 to 2.7%. Sera from subjects on diets of high or low linoleic acid content were analyzed to study the effect of the fatty acid portion of serum cholesterol esters; the differences between values obtained with the comparison method and the direct method was insignificant on both diets. We conclude that the use of serum calibrators eliminates the bias inherent in the direct method.


The following articles in journals at HighWire Press have cited this article:


Home page
J Am Board Fam MedHome page
C. van Weel, C. Bakx, H. van den Hoogen, T. Thien, and W. van den Bosch
Long-term Outcome of Cardiovascular Prevention: A Nijmegen Academic Family Practices Network Study
J Am Board Fam Med, January 1, 2006; 19(1): 62 - 68.
[Abstract] [Full Text] [PDF]


Home page
Int J EpidemiolHome page
M. A Pereira, R. M Weggemans, D. R Jacobs Jr, P. J Hannan, P. L Zock, J. M Ordovas, and M. B Katan
Within-person variation in serum lipids: implications for clinical trials
Int. J. Epidemiol., June 1, 2004; 33(3): 534 - 541.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.