Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 1505-1509, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rakhit, A.
Right arrow Articles by Riegelman, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rakhit, A.
Right arrow Articles by Riegelman, S.

Clinical Chemistry, Vol 28, 1505-1509, Copyright © 1982 by American Association for Clinical Chemistry

Improved liquid-chromatographic assay of quinidine and its metabolites in biological fluids

A Rakhit, M Kunitani, NH Holford and S Riegelman

We describe a simple, rapid, and specific assay for quinidine and its known metabolites in plasma, urine, and bile. Plasma proteins are precipitated by adding acetonitrile, which also contains the internal standard. The supernatant fluid is evaporated and the reconstituted residue is separated on a reversed-phase column, with fluorescence detection. The standard curve is linear and results are reproducible over the clinical concentration ranges: quinidine 0.4 to 8.0 mg/L and the three metabolites (quinidine 10,11-diol, 3-hydroxyquinidine, and quinidine-N-oxide) 0.05 to 1.5 mg/L. As little as 10 micrograms of the N-oxide metabolite per liter and 1 microgram of the other analytes per liter can be quantitated in 0.5 mL of plasma, urine, or bile. With the use of an automated chromatographic system, many samples can be analyzed in a continuous run.


The following articles in journals at HighWire Press have cited this article:


Home page
J Clin PharmacolHome page
L. E. Pope, M. H. Khalil, J. E. Berg, M. Stiles, G. J. Yakatan, and E. M. Sellers
Pharmacokinetics of Dextromethorphan After Single or Multiple Dosing in Combination With Quinidine in Extensive and Poor Metabolizers
J. Clin. Pharmacol., October 1, 2004; 44(10): 1132 - 1142.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.