Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 28: 1956-1961, 1982;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cho, H. K.
Right arrow Articles by Olson, C. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cho, H. K.
Right arrow Articles by Olson, C. L.

Clinical Chemistry, Vol 28, 1956-1961, Copyright © 1982 by American Association for Clinical Chemistry

Development of a multichannel electrochemical centrifugal analyzer

HK Cho, YH Lee, RA Couch, JM Jagadeesh and CL Olson

A new instrument has been developed that is similar in design and concept to the GeMSAEC centrifugal analyzer (Oak Ridge National Laboratory) except that electrochemical detection is used rather than optical detection. The present version has eight channels, each with its own detector. Problems of speed control and sampling synchronization are greatly minimized from those of a multichannel centrifugal analyzer having a single detector system. All eight sample compartments and polarographic cells are contained in a single Teflon rotor, 7.7 cm in diameter. The working electrodes are planar carbon electrodes. The initial application of the analyzer is in kinetic methods involving the rates of enzyme-catalyzed reactions. The initial system chosen was the glucose oxidase system. When the rotor is spun, the solution moves into the sample cell and up against the planar working electrode. The reaction starts and current is measured as a function of time at a constant applied voltage. The current output from each polarographic circuit is connected to a separate channel of a multiplexed analog-to-digital converter. The analyzer is controlled by a dedicated microcomputer system, which sets the polarographic cell voltages, collects the current-time data, and calculates the results.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1982 by the American Association for Clinical Chemistry.