Clinical Chemistry 29: 16-20, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Potezny, N.
Right arrow Articles by Conyers, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Potezny, N.
Right arrow Articles by Conyers, R. A.

Clinical Chemistry, Vol 29, 16-20, Copyright © 1983 by American Association for Clinical Chemistry

Urinary oxalate determination by use of immobilized oxalate oxidase in a continuous-flow system

N Potezny, R Bais, PD O'Loughlin, JB Edwards, AM Rofe and RA Conyers

In this procedure, oxalate oxidase (EC 1.2.3.4) immobilized in a continuous-flow system is used to determine oxalate in urine. The hydrogen peroxide formed from oxalate is detected by use of a color reaction with peroxidase (EC 1.11.1.7), 3-methyl-2-benzothiazoline hydrazine, and N,N-dimethylalanine. However, urine contains an oxalate oxidase inhibitor, which cannot be removed by heating, ion-exchange resins, or cellulose columns. This makes it necessary to precipitate the oxalate before assay. The overall assay system is accurate (oxalate recovery, 95.9%), sensitive (less than or equal to 5 mumol/L), precise (within-batch CV less than 1.25%, between-batch CV less than 5%), and relatively rapid (60 samples per working day). The assay system has better accuracy than an established chemical method and a gas- chromatographic method, and is considerably less arduous than and correlates well (r = 0.94) with a modified chemical method. The reference interval for urinary oxalate excretion is 0.16-0.56 mmol per day (n = 97). Only nonphysiological concentrations of ascorbate interfere with the assay, by increasing the oxalate result in the overall assay, presumably by post-micturition formation of oxalate from ascorbate in the urine samples.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
P. M. Ladwig, R. R. Liedtke, T. S. Larson, and J. C. Lieske
Sensitive Spectrophotometric Assay for Plasma Oxalate
Clin. Chem., December 1, 2005; 51(12): 2377 - 2380.
[Full Text] [PDF]


Home page
JAMAHome page
R. A. J. Conyers, R. Bais, and A. M. Rofe
Oxalosis and the E-Ferol Toxicity Syndrome
JAMA, November 21, 1986; 256(19): 2677 - 2678.
[Abstract] [PDF]