Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 25-30, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harris, E. K.
Right arrow Articles by Yasaka, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harris, E. K.
Right arrow Articles by Yasaka, T.

Clinical Chemistry, Vol 29, 25-30, Copyright © 1983 by American Association for Clinical Chemistry

On the calculation of a "reference change" for comparing two consecutive measurements

EK Harris and T Yasaka

We describe a statistical method for calculating a "reference change," defined as that difference between two consecutive test results in an individual that is statistically significant in a given proportion of all similar persons. By allowing for variation in within-person variances, this procedure computes a reference change that is more specific (i.e., less prone to false positives) than that obtained directly from the distribution of observed differences between measurements. Moreover, the method may easily be extended to a test for trend in three successive measurements. The method has been applied to semi-annual measurements of serum calcium and alkaline phosphatase in 698 men and women enrolled in a large health-maintenance program. We believe that these ideas may also be usefully applied to successive laboratory tests in carefully defined patient populations--but this introduces special problems, which are discussed briefly.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
V. Garcia Moreira, B. Prieto Garcia, J. M. Baltar Martin, F. Ortega Suarez, and F. V. Alvarez
Cell-Free DNA as a Noninvasive Acute Rejection Marker in Renal Transplantation
Clin. Chem., November 1, 2009; 55(11): 1958 - 1966.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
L. J. Lefkowitz, J. M. Kupina, N. L. Hirth, R. M. Henry, G. Y. Noland, J. Y. Barbee Jr, J. Y. Zhou, and C. B. Weese
Intraindividual Stability of Human Erythrocyte Cholinesterase Activity
Clin. Chem., July 1, 2007; 53(7): 1358 - 1363.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
M. Schou, F. Gustafsson, P. H. Nielsen, L. H. Madsen, A. Kjaer, and P. R. Hildebrandt
Unexplained week-to-week variation in BNP and NT-proBNP is low in chronic heart failure patients during steady state
Eur J Heart Fail, January 1, 2007; 9(1): 68 - 74.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
M. R. Fokkema, Z. Herrmann, F. A.J. Muskiet, and J. Moecks
Reference change values for brain natriuretic peptides revisited.
Clin. Chem., August 1, 2006; 52(8): 1602 - 1603.
[Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
B. Comin-Anduix, A. Gualberto, J. A. Glaspy, E. Seja, M. Ontiveros, D. L. Reardon, R. Renteria, B. Englahner, J. S. Economou, J. Gomez-Navarro, et al.
Definition of an Immunologic Response Using the Major Histocompatibility Complex Tetramer and Enzyme-Linked Immunospot Assays
Clin. Cancer Res., January 1, 2006; 12(1): 107 - 116.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
G. Soletormos, A. Semjonow, P. E.C. Sibley, R. Lamerz, P. H. Petersen, W. Albrecht, P. Bialk, M. Gion, F. Junker, H.-P. Schmid, et al.
Biological Variation of Total Prostate-Specific Antigen: A Survey of Published Estimates and Consequences for Clinical Practice
Clin. Chem., August 1, 2005; 51(8): 1342 - 1351.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Trape, J. Perez de Olaguer, J. Buxo, and L. Lopez
Biological Variation of Tumor Markers and Its Application in the Detection of Disease Progression in Patients with Non-Small Cell Lung Cancer
Clin. Chem., January 1, 2005; 51(1): 219 - 222.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
J. Trape, J. M. Botargues, F. Porta, C. Ricos, J. M. Badal, R. Salinas, M. Sala, and A. Roca
Reference Change Value for {alpha}-Fetoprotein and Its Application in Early Detection of Hepatocellular Carcinoma in Patients with Hepatic Disease
Clin. Chem., July 1, 2003; 49(7): 1209 - 1211.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
X. Fuentes-Arderiu and B. Gonzalez-de-la-Presa
Interchangeability of Estimates of Day-to-Day Imprecision between Commercial Control Materials and Serum Pools
Clin. Chem., March 1, 2002; 48(3): 573 - 574.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Biosca, C. Ricos, R. Lauzurica, R. Galimany, and P. Hyltoft Petersen
Reference Change Value Concept Combining Two Delta Values to Predict Crises in Renal Posttransplantation
Clin. Chem., December 1, 2001; 47(12): 2146 - 2148.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
K. Rasmussen, J. Moller, and M. Lyngbak
Within-Person Variation of Plasma Homocysteine and Effects of Posture and Tourniquet Application
Clin. Chem., October 1, 1999; 45(10): 1850 - 1855.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
J. S. Krop, J. Coresh, L. E. Chambless, E. Shahar, R. L. Watson, M. Szklo, and F. L. Brancati
A Community-Based Study of Explanatory Factors for the Excess Risk for Early Renal Function Decline in Blacks vs Whites With Diabetes: The Atherosclerosis Risk in Communities Study
Arch Intern Med, August 9, 1999; 159(15): 1777 - 1783.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
O. Ahokoski, A. Virtanen, V. Kairisto, H. Scheinin, R. Huupponen, and K. Irjala
Biological Day-to-Day Variation and Reference Change Limits of Serum Cortisol and Aldosterone in Healthy Young Men on Unrestricted Diets
Clin. Chem., July 1, 1999; 45(7): 1097 - 1099.
[Full Text] [PDF]


Home page
Clin. Chem.Home page
C. Biosca, C. Ricos, C. V. Jimenez, R. Lauzurica, and R. Galimany
Model for Establishing Biological Variation in Nonhealthy Situations: Renal Posttransplantation Data
Clin. Chem., November 1, 1997; 43(11): 2206 - 2208.
[Full Text]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
V. A. Carroll, M. R. Griffiths, M. Geiger, C. Merlo, M. Furlan, B. Lammle, and B. R. Binder
Plasma Protein C Inhibitor Is Elevated in Survivors of Myocardial Infarction
Arterioscler Thromb Vasc Biol, January 1, 1997; 17(1): 114 - 118.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
U. C. Garg, Z.-J. Zheng, A. R. Folsom, Y. S. Moyer, M. Y. Tsai, P. McGovern, and J. H. Eckfeldt
Short-term and long-term variability of plasma homocysteine measurement
Clin. Chem., January 1, 1997; 43(1): 141 - 145.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.