Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 438-446, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sherwood, M. J.
Right arrow Articles by Chen, S. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sherwood, M. J.
Right arrow Articles by Chen, S. T.

Clinical Chemistry, Vol 29, 438-446, Copyright © 1983 by American Association for Clinical Chemistry

A new reagent strip (Visidex) for determination of glucose in whole blood

MJ Sherwood, ME Warchal and ST Chen

A new solid-phase reagent strip for determination of glucose in whole blood, Visidex, has been developed specifically for visual use in conjunction with a calibrated color scale. Two reagent pads are used, each formulated for a different portion of the range of clinical values, to maximize the visual resolution available to the user. Colorimetric examination of reacted reagent pads indicated that the label color blocks match closely the appearance of the reagent pads; that the reagent pads exhibit good precision; and that the colors of the reagent pads are independent of operator technique, sample volume (20-50 microL), and effects of potential interferents studied (although high concentrations of fluoride slightly inhibited color development). Glucose measurements obtained visually with the Visidex system correlated well with values obtained with a YSI Glucose Analyzer (for two separate studies, slope = 0.96 and 1.04, r = 0.99 and 0.96, and n = 172 and 543, respectively).


The following articles in journals at HighWire Press have cited this article:


Home page
ANN INTERN MEDHome page
S. H. Atkin, A. Dasmahapatra, M. A. Jaker, M. I. Chorost, and S. Reddy
Fingerstick Glucose Determination in Shock
Ann Intern Med, June 1, 1991; 114(12): 1020 - 1024.