Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 456-461, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ji, S. Q.
Right arrow Articles by Evenson, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ji, S. Q.
Right arrow Articles by Evenson, M. A.

Clinical Chemistry, Vol 29, 456-461, Copyright © 1983 by American Association for Clinical Chemistry

Effects of contaminants in blood-collection devices on measurements of therapeutic drugs

SQ Ji and MA Evenson

Substances in evacuated blood-collection devices produce gas- chromatographic peaks with retention times similar to those of drugs. All tubes tested except the serum separator tubes contained tris(2- butoxyethyl) phosphate, as determined by mass spectrometry. In addition, the partition coefficient during the solvent-extraction step increased for some drugs by as much as 40%, while for other drugs it decreased by as much as 30%, depending on the drug and the collection tube. The Becton Dickinson serum separator tube also contains several other compounds identified by mass spectrometry to be dibasic esters used in the preparation of the polyester gel. The Corning serum separator tube and the Venoject serum tube contain still other impurities. The Becton Dickinson royal-blue-stoppered tube contained the least amount of impurities of the tubes tested. CVs of 25 commonly measured drugs in plasma pools increased from 5% for samples collected in glass tubes to greater than 20% for samples collected in evacuated blood-collection tubes. Clearly, accuracy and precision of measurements of therapeutic drugs can be seriously compromised if an inappropriate blood-collection device is used.