Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 1080-1082, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Little, R. R.
Right arrow Articles by Goldstein, D. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Little, R. R.
Right arrow Articles by Goldstein, D. E.

Clinical Chemistry, Vol 29, 1080-1082, Copyright © 1983 by American Association for Clinical Chemistry

Glycosylated hemoglobin measured by affinity chromatography: micro- sample collection and room-temperature storage

RR Little, JD England, HM Wiedmeyer and DE Goldstein

Under proper conditions, whole blood can be stored at room temperature for as long as 21 days before measurement of glycosylated hemoglobin by affinity chromatography. Whole blood (anticoagulated with EDTA or heparin) was placed in capillary tubes, which were then sealed at both ends and stored at room temperature. Just before assay, whole blood was rinsed from the tubes and diluted 10-fold with water. Samples of each patient's blood were assayed as whole-blood hemolysates by affinity chromatography after zero, seven, 14, and 21 days of storage. Values for glycosylated hemoglobin did not change over 21 days of storage and values for each storage day correlated well (r = 0.97, p less than .0001) with hemoglobin A1C measured in fresh erythrocyte hemolysates by "high-performance" liquid ion-exchange chromatography.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
D. B. Sacks, D. E. Bruns, D. E. Goldstein, N. K. Maclaren, J. M. McDonald, and M. Parrott
Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus
Clin. Chem., March 1, 2002; 48(3): 436 - 472.
[Abstract] [Full Text] [PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
T. E. Seeman, B. S. McEwen, J. W. Rowe, and B. H. Singer
Allostatic load as a marker of cumulative biological risk: MacArthur studies of successful aging
PNAS, March 29, 2001; (2001) 81072698.
[Abstract] [Full Text]


Home page
The Diabetes EducatorHome page
A. E. Maxwell, I. F. Hunt, and M. A. Bush
Effects of a Social Support Group, as an Adjunct to Diabetes Training, on Metabolic Control and Psychosocial Outcomes
The Diabetes Educator, January 1, 1992; 18(4): 303 - 309.
[PDF]


Home page
Proc. Natl. Acad. Sci. USAHome page
T. E. Seeman, B. S. McEwen, J. W. Rowe, and B. H. Singer
Allostatic load as a marker of cumulative biological risk: MacArthur studies of successful aging
PNAS, April 10, 2001; 98(8): 4770 - 4775.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.