Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 1471-1473, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wimberley, P. D.
Right arrow Articles by Siggaard- Andersen, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wimberley, P. D.
Right arrow Articles by Siggaard- Andersen, O.

Clinical Chemistry, Vol 29, 1471-1473, Copyright © 1983 by American Association for Clinical Chemistry

Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults

PD Wimberley, KG Pedersen, J Thode, N Fogh-Andersen, AM Sorensen and O Siggaard- Andersen

Transcutaneous carbon dioxide and oxygen tensions (tc-pCO2 and tc-pO2) were measured in seven healthy adult volunteers during hyperventilation in atmospheric air and during CO2 inhalation. Three skin sensors were applied to each subject: an O2 electrode, a CO2 electrode, and a combined O2-CO2 electrode, each heated to 44 degrees C. We observed close correlation between tc-pCO2 and capillary-pCO2, the relation being close to that calculated from the anaerobic temperature coefficient of pCO2 in blood. For O2, on the other hand, the relationship between transcutaneous and capillary values appeared more complex. Electrode drift during in-vivo monitoring was greater for pCO2 (up to 12%) than for pO2 (up to 7%), but generally we observed no differences in drift between the combined and the single electrodes. We conclude that tc-pCO2 measured with a single or a combined electrode reliably predicts capillary-pCO2 in healthy adults and that changes are rapidly observed. Our conclusions regarding tc-pO2 values are less definite because of uncertain interpretation of the capillary-pO2 values.


The following articles in journals at HighWire Press have cited this article:


Home page
ChestHome page
J. H. Storre, B. Steurer, H.-J. Kabitz, M. Dreher, and W. Windisch
Transcutaneous PCO2 Monitoring During Initiation of Noninvasive Ventilation
Chest, December 1, 2007; 132(6): 1810 - 1816.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. Bakovic, D. Eterovic, Z. Valic, Z. Saratlija-Novakovic, I. Palada, A. Obad, and Z. Dujic
Increased pulmonary vascular resistance and reduced stroke volume in association with CO2 retention and inferior vena cava dilatation
J Appl Physiol, September 1, 2006; 101(3): 866 - 872.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
F. J. Curley and N. A. Smyrnios
Routine Monitoring of Critically I11 Patients
J Intensive Care Med, July 1, 1990; 5(4): 153 - 174.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.