Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 1488-1493, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Houser, M. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Houser, M. T.

Clinical Chemistry, Vol 29, 1488-1493, Copyright © 1983 by American Association for Clinical Chemistry

Improved turbidimetric assay for lysozyme in urine

MT Houser

I describe an improved turbidimetric assay for lysozyme in urine. This method is simple, reproducible, linear over a 100-fold concentration range, sensitive to concentrations as low as 10 micrograms/L, and only commercially available products are required. Evaluation of urinary lysozyme concentration with this assay demonstrated a within-run and between-run CV of 9.9% and 4.8%, respectively, for normal urine, minimal chemical interference, and a mean analytical recovery of 104.8%. There were differences in the rate of clearing and in the linearity of the assay with use of three commercial preparations of Micrococcus lysodeikticus, and significant differences in results when different lysozyme standards were used. Reference values were established by use of data on 169 healthy subjects, ages six months to 61 years. Clinical efficacy of the assay was demonstrated in children with renal disorders, especially those associated with chronic renal failure or tubular dysfunction.


The following articles in journals at HighWire Press have cited this article:


Home page
IOVSHome page
M. J. Glasson, F. Stapleton, L. Keay, D. Sweeney, and M. D. P. Willcox
Differences in Clinical Parameters and Tear Film of Tolerant and Intolerant Contact Lens Wearers
Invest. Ophthalmol. Vis. Sci., December 1, 2003; 44(12): 5116 - 5124.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS