Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 29: 1628-1634, 1983;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Li, T. M.
Right arrow Articles by Hydo, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Li, T. M.
Right arrow Articles by Hydo, S. J.

Clinical Chemistry, Vol 29, 1628-1634, Copyright © 1983 by American Association for Clinical Chemistry

Automated fluorometer/photometer system for homogeneous immunoassays

TM Li, SP Robertson, TH Crouch, EE Pahuski, GA Bush and SJ Hydo

A fully automated bench-top clinical analyzer (OPTIMATE TM; Ames/Gilford) performs homogeneous fluorescent immunoassays, colorimetric immunoassays, and determinations of routine blood analytes; drugs, enzymes, metabolites, specific proteins, and hormones in serum. Unique features include a combination fluorescence/absorbance aspirating thermocuvette, a photon-counting fluorometer/photometer, a multi-reagent distribution valve to dispense as many as three reagents plus buffer, and a user-replaceable programmable memory cartridge for software updates. We have evaluated the performance of OPTIMATE substrate-labeled fluorescent immunoassays for gentamicin, tobramycin, amikacin, theophylline, phenytoin, phenobarbital, primidone, carbamazepine, and quinidine with this automated system. A sample throughput of 92 samples per hour is achieved by reading fixed-point fluorescence results every 39 s after an initial 4-min reaction period. Precision studies indicate typical CVs of less than or equal to 6% for mid-range controls. Standard curves can be reused for as long as two weeks before recalibration. With clinical samples, results by the OPTIMATE procedure correlated well (r greater than or equal to 0.97) with those by a reference method.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1983 by the American Association for Clinical Chemistry.