Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1620-1624, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maynard, Y.
Right arrow Articles by Ladenson, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maynard, Y.
Right arrow Articles by Ladenson, J. H.

Clinical Chemistry, Vol 30, 1620-1624, Copyright © 1984 by American Association for Clinical Chemistry

Radioimmunoassay of apolipoprotein B with use of monoclonal antibodies

Y Maynard, DC Roden, MJ Tikkanen, G Schonfeld and JH Ladenson

We describe a double-antibody radioimmunoassay for apolipoprotein B with use of monoclonal antibodies. Values for 32 patients with various lipid disorders, obtained with use of one of the monoclonal antibodies (464B1B6), were similar to those obtained with use of a polyclonal antiserum. When we used another monoclonal antibody (465C3D1) the values were significantly lower. Monoclonal antibody 464B1B6 recognized apolipoprotein B determinants in the very-low-density-lipoprotein and low-density-lipoprotein fractions of plasma in a similar fashion as in unfractionated plasma, but monoclonal 465C3D1 gave lower values with the fractionated plasma. For precipitation of the antibody- apolipoprotein complex to be complete, use of polyethylene glycol was necessary with one of the monoclonal antibodies but not with the other. The interassay CV was 12.3% and 11.6% for the assays with the monoclonal antibodies. Analytical recoveries ranged from 85 to 94%. Owing to variations in the B50 from one preparation of standard to another, we found it necessary to normalize the results to those of a serum pool. We conclude that certain monoclonal antibodies can be used effectively in radioimmunoassays for apolipoprotein B in plasma and may help in the standardization of these assays.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.