Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1672-1674, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smith, N. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smith, N. B.

Clinical Chemistry, Vol 30, 1672-1674, Copyright © 1984 by American Association for Clinical Chemistry

Determination of volatile alcohols and acetone in serum by non-polar capillary gas chromatography after direct sample injection

NB Smith

In this method for detection and quantification of volatile alcohols by capillary gas chromatography, the serum sample is deproteinized, then directly injected into the gas chromatograph with 1-propanol as the internal standard. The capillary column is a 30-m bonded methylsilicone- coated, fused-silica column. With helium as the carrier gas, the injector inlet is set at a split ratio of 1/30 and the average linear velocity in the column is 25 cm/s. Injector and flame-ionization detector temperatures are 280 degrees C, oven temperature 35 degrees C. Chromatography time is less than 3 min.


The following articles in journals at HighWire Press have cited this article:


Home page
Proc. Natl. Acad. Sci. USAHome page
I.-M. Jonsson, M. Verdrengh, M. Brisslert, S. Lindblad, M. Bokarewa, U. Islander, H. Carlsten, C. Ohlsson, K. S. Nandakumar, R. Holmdahl, et al.
From the Cover: Ethanol prevents development of destructive arthritis
PNAS, January 2, 2007; 104(1): 258 - 263.
[Abstract] [Full Text] [PDF]


Home page
Toxicol SciHome page
H. A. Barton, P. J. Deisinger, J. C. English, J. M. Gearhart, W. D. Faber, T. R. Tyler, M. I. Banton, J. Teeguarden, and M. E. Andersen
Family Approach for Estimating Reference Concentrations/Doses for Series of Related Organic Chemicals
Toxicol. Sci., March 1, 2000; 54(1): 251 - 261.
[Abstract] [Full Text] [PDF]


Home page
Drug Metab. Dispos.Home page
R. J. Boatman, L. G. Perry, L. A. Fiorica, J. C. English, R. W. Kapp Jr., C. Bevan, T. R. Tyler, M. I. Banton, and G. A. Wright
Dermal Absorption and Pharmacokinetics of Isopropanol in the Male and Female F-344 Rat
Drug Metab. Dispos., March 1, 1998; 26(3): 197 - 202.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.