Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1686-1688, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lloyd, D.
Right arrow Articles by Marples, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lloyd, D.
Right arrow Articles by Marples, J.

Clinical Chemistry, Vol 30, 1686-1688, Copyright © 1984 by American Association for Clinical Chemistry

Simple colorimetry of glycated serum protein in a centrifugal analyzer

D Lloyd and J Marples

A recently described (Clin Chim Acta 127: 87-95, 1982) colorimetric assay for glycated proteins in serum exploits their ketoamine activity to reduce 3,3'-(3,3'-dimethoxy-4,4'-biphenylylene)bis [2-(p- nitrophenyl)-5-phenyl-2H-tetrazolium chloride] (nitroblue tetrazolium) in alkaline solution; the authors termed this the "fructosamine assay." The method is simple, requiring only the addition of one reagent and measurement of the absorbance change during 5 min; results are expressed relative to a synthetic standard. We have adapted this for use in a centrifugal analyzer and report its performance, both analytically and as an index of hyperglycemia. Precision is good (between-batch CV 2.1%), the reagent is stable and inexpensive, and the procedure is rapid (75 samples per hour). Albumin influences the measurement, but for concentrations greater than or equal to 35 g/L this was not a serious problem. Normal and diabetic populations can be clearly discriminated (p less than 0.001). The test detected 25 (84%) of the 30 untreated diabetics studied and gave four false positives (8%). The results correlate well with those for glucose in plasma of fasting subjects (r = 0.87) and for hemoglobin A1 (r = 0.80).