Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 2003-2007, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hodges, S. C.
Right arrow Articles by Hirata, A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hodges, S. C.
Right arrow Articles by Hirata, A. A.

Clinical Chemistry, Vol 30, 2003-2007, Copyright © 1984 by American Association for Clinical Chemistry

Effect of heat and sodium dodecyl sulfate on solubilization of proteins before two-dimensional polyacrylamide gel electrophoresis

SC Hodges and AA Hirata

To solubilize biological samples, sodium dodecyl sulfate (SDS) frequently is added and the mixture heated at 70-100 degrees C. However, two-dimensional polyacrylamide gel electrophoresis of a single protein after SDS treatment has not been reported. When rabbit-muscle creatine kinase was so run, we saw considerable difference in the gel staining pattern for the heated and nonheated enzyme dissolved in the SDS solution. After heating for 10 min at 95 degrees C the number of silver-stained spots apparent increased, and staining of several spots intensified. After 60 min, most of the discrete spots disappeared. Evidently the peptide backbone had been hydrolyzed. When the enzyme was simply left at room temperature for four days, the effects were similar. Appearance of new spots and loss of spots apparently are caused by heating alone but are intensified by SDS. Experiments with human serum albumin yielded similar results.


The following articles in journals at HighWire Press have cited this article:


Home page
IOVSHome page
M. Goralska, L. N. Fleisher, and M. C. McGahan
Ferritin H- and L-Chains in Fiber Cell Canine and Human Lenses of Different Ages
Invest. Ophthalmol. Vis. Sci., September 1, 2007; 48(9): 3968 - 3975.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.