Clinical Chemistry Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 185-187, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shah, H.
Right arrow Articles by Adlercreutz, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shah, H.
Right arrow Articles by Adlercreutz, H.

Clinical Chemistry, Vol 30, 185-187, Copyright © 1984 by American Association for Clinical Chemistry

Direct solid-phase fluoroenzymeimmunoassay of 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide in urine

H Shah, AM Saranko, M Harkonen and H Adlercreutz

A competitive solid-phase fluoroenzymeimmunoassay has been developed for rapidly measuring 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha- glucuronide (Pd-3G) directly in diluted specimens of pre-breakfast urine. The assay involves use of an antiserum to Pd-3G and enzyme- labeled antigen prepared by chemically linking glucose-6-phosphate dehydrogenase (EC 1.1.1.49) to Pd-3G. Antibody-bound and free antigen are separated by use of a solid-phase double antibody: sheep anti- rabbit gamma-globulin coupled to cellulose particles. The solid phase, isolated by centrifugation, is washed free of labeled antigen and endogenous enzyme interferences. Enzyme activity in the bound fraction is then measured fluorometrically with glucose 6-phosphate as the substrate and generated NADPH as a fluorogenic indicator of enzyme activity. The assay is sufficiently sensitive (30-35 pg per assay tube), specific, and reliable for routine use, and results correlate well (r = 0.98) with those by an established specific radioimmunoassay. Because it is suited to routine use, this assay may be applied to detecting ovulation, assessing the function of corpus luteum, and monitoring early pregnancy.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.