Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 206-210, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Roda, A.
Right arrow Articles by Bovara, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Roda, A.
Right arrow Articles by Bovara, R.

Clinical Chemistry, Vol 30, 206-210, Copyright © 1984 by American Association for Clinical Chemistry

Continuous-flow determination of primary bile acids, by bioluminescence, with use of nylon-immobilized bacterial enzymes

A Roda, S Girotti, S Ghini, B Grigolo, G Carrea and R Bovara

We describe a continuous-flow bioluminescence method for measuring primary bile acid in serum, with nylon as the solid support. 7 alpha- Hydroxysteroid dehydrogenase (EC 1.1.1. 159), a bacterial luciferase (EC 1.14.14.3), and NAD+:FMN oxido-reductase (EC 1.6.8.1) are covalently co-immobilized on a nylon coil (1 m X 1.0 mm i.d.). The assay is highly specific for 7 alpha-hydroxy bile acids. Other bile acids and steroids do not interfere. The continuous-flow light-emitting system, in which the reactor (nylon coil) is placed in front of a photomultiplier tube inside a luminometer, is versatile and simple. The flow is air-segmented, and serum samples (5-50 microL) can be injected directly. Concentration and response are linearly related from 10 to 2500 pmol per assay tube. The precision of the method is satisfactory (CV 5-10%), both inter- and intra-assay. We validated the technique by comparing results with those by RIA, enzyme immunoassay, and "high- performance" liquid chromatography. More than 20 samples an hour can be analyzed, with no carryover. The nylon-immobilized enzymes are stable for more than two months, and greater than 500 samples can be analyzed with use of a few milligrams of enzymes. Normal values for bile acid content of serum ranged from 1 to 2.5 mumol/L, in agreement with those obtained by other methods.