Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 443-446, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Eckfeldt, J. H.
Right arrow Articles by Dahl, I. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Eckfeldt, J. H.
Right arrow Articles by Dahl, I. I.

Clinical Chemistry, Vol 30, 443-446, Copyright © 1984 by American Association for Clinical Chemistry

Direct analysis for urinary protein with biuret reagent, with use of urine ultrafiltrate blanking: comparison with a manual biuret method involving trichloroacetic acid precipitation

JH Eckfeldt, MJ Kershaw and II Dahl

We describe a method for measuring urinary protein with a centrifugal analyzer. Biuret reagent is used, and blanking with an ultrafiltrate of urine eliminates interferences from the nonprotein, biuret-positive chromogens in urine. We compare results by this new method with those by a manual method in which trichloroacetic acid precipitation and biuret reagent are used. The new method shows good precision and excellent correlation (r = 0.997) with the manual method. The ease and convenience of this assay should make this a useful method for the routine clinical laboratory.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
G. L. Hortin and B. Meilinger
Cross-Reactivity of Amino Acids and Other Compounds in the Biuret Reaction: Interference with Urinary Peptide Measurements
Clin. Chem., August 1, 2005; 51(8): 1411 - 1419.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.