Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 619-626, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Patterson, D. G.
Right arrow Articles by Bayse, D. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Patterson, D. G.
Right arrow Articles by Bayse, D. D.

Clinical Chemistry, Vol 30, 619-626, Copyright © 1984 by American Association for Clinical Chemistry

Determination of steroid hormones in a human-serum reference material by isotope dilution--mass spectrometry: a candidate definitive method for cortisol

DG Patterson, MB Patterson, PH Culbreth, DM Fast, JS Holler, EJ Sampson and DD Bayse

We report a method, based on isotope dilution--mass spectrometry, for determining cortisol in a pooled specimen of human serum. Isotopically labeled cortisol is added to 5.0 mL of serum so that the molar concentrations of labeled cortisol and unlabeled cortisol are approximately equal. The specimen and two calibration standards are extracted with dichloromethane, and the extracted cortisol is converted to the methoxime-trimethylsilyl ether derivative. Samples and standards are analyzed by gas chromatography--mass spectrometry by monitoring the peak areas for m/z 605 and 608. The cortisol concentration is calculated by linear interpolation between the two bracketing standards. Variances of data collected during six weeks showed that the overall coefficient of variation (CV) was 0.69% (n = 32); the within- vial CV, 0.63%; the among-vial CV, 0.22%; and the among-day CV, 0.15% (means = 3.973 nmol/vial). Method specificity was demonstrated by liquid chromatographic as well as C8 mini-column cleanup of samples before derivation, by alternative ion monitoring at m/z 636 and 639, and by negative-ion chemical ionization at m/z 459 and 462. Derivatives of all observed degradation products of cortisol under basic, neutral, and acidic conditions did not interfere.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
D. H. Chace, B. W. Adam, S. J. Smith, J. R. Alexander, S. L. Hillman, and W. H. Hannon
Validation of Accuracy-based Amino Acid Reference Materials in Dried-Blood Spots by Tandem Mass Spectrometry for Newborn Screening Assays
Clin. Chem., August 1, 1999; 45(8): 1269 - 1277.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS