Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1128-1136, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bowers, G. N.
Right arrow Articles by McComb, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bowers, G. N., Jr
Right arrow Articles by McComb, R. B.

Clinical Chemistry, Vol 30, 1128-1136, Copyright © 1984 by American Association for Clinical Chemistry

A unifying reference system for clinical enzymology: aspartate aminotransferase and the International Clinical Enzyme Scale

GN Bowers Jr and RB McComb

A review of methodology for determining aspartate aminotransferase (ASAT; EC 2.6.1.1), including recent national and international recommendations, indicates that standardization of methodology alone will not bring interlaboratory compatibility of ASAT results. We propose that an additional component to standardization is needed, namely, enzyme reference materials. Furthermore, we suggest that stable, well-defined ASAT materials from human sources are currently available. These primary reference materials and the state-of-the-art IFCC Reference Method for ASAT provide the basis for a unifying reference system for ASAT. Given such a reference system, we propose a practical way to promote compatibility of currently incompatible numerical results for ASAT through the use of one ASAT scale of units, the "International Clinical Enzyme Scale." This scale-unification concept would permit all current methods, instruments, and temperature choices to be used for ASAT determinations in the daily working laboratory. We present illustrative examples and demonstrate the unique ability of this concept to promote compatibility of the ASAT results from numerous laboratories using many different ASAT methods.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
A. R. Henderson, S. Krishnan, S. Webb, C. M. Cheung, D. J. Nazir, and H. Richardson
Proficiency testing of creatine kinase and creatine kinase-2: the experience of the Ontario Laboratory Proficiency Testing Program
Clin. Chem., January 1, 1998; 44(1): 124 - 133.
[Abstract] [Full Text] [PDF]