Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1216-1218, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brown, S.
Right arrow Articles by Savory, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brown, S.
Right arrow Articles by Savory, J.

Clinical Chemistry, Vol 30, 1216-1218, Copyright © 1984 by American Association for Clinical Chemistry

Electrothermal atomic absorption spectrometric determination of aluminum in serum with a new technique for protein precipitation

S Brown, RL Bertholf, MR Wills and J Savory

We have studied the electrothermal atomic absorption measurement of aluminum in serum samples by direct analysis with standard additions and the use of a matrix modifier. We have also measured aluminum by analysis of the supernate after pretreatment of serum with concentrated nitric acid to precipitate proteins, and have compared the results obtained by these two techniques. Both appear to eliminate interferences arising from the serum matrix. We quantified the aluminum by utilizing a stabilized temperature (L'vov) platform. Within-run precision (CV) for the standard-additions method was 16.6% (means = 6.5 micrograms/L) and 6.0% (means = 86.8 micrograms/L) and for the protein precipitation method was 10.1% (means = 10.9 micrograms/L) and 4.2% (means = 88.5 micrograms/L). Linearity of the standard curve extended from 0 to 120 micrograms/L for the standard-additions method and from 0 to 100 micrograms/L for the protein precipitation method. Samples from 38 patients were analyzed by both techniques, and linear regression analysis yielded the equation y (protein precipitation) = 1.02 X (standard additions) + 2.04.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.