Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1233-1237, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lockitch, G.
Right arrow Articles by Hawkley, L. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lockitch, G.
Right arrow Articles by Hawkley, L. C.

Clinical Chemistry, Vol 30, 1233-1237, Copyright © 1984 by American Association for Clinical Chemistry

Evaluation of the Amniostat-FLM assay for assessment of fetal lung maturity

G Lockitch, BK Wittmann, SM Mura and LC Hawkley

Results of the "Amniostat-FLM" assay, a rapid semiquantitative test for phosphatidylglycerol, were compared with determinations of the lecithin/sphingomyelin (L/S) ratio, with phosphatidylglycerol measured by two-dimensional thin-layer chromatography, and with results of the "shake test" for 94 specimens of amniotic fluid. Correlation between results with the Amniostat and the other tests was excellent. All four tests are very accurate when predicting lung maturity. The predictive value of a negative test, i.e., that hyaline membrane disease would not occur, was between 92 and 100%. However, the accuracy of predicted lung immaturity is poor. For all four tests, predictions of lung immaturity were incorrect in more than 50% of the cases. Of the 49 infants born within 72 h of testing, none developed hyaline membrane disease when phosphatidylglycerol was detectable by either method or when the shake test indicated fetal lung maturity, but three infants with L/S ratio greater than 2/1 did develop the disease. The Amniostat provides a rapid screening method for detecting phosphatidylglycerol in amniotic fluid, which could well replace the thin-layer chromatographic method for measuring phosphatidylglycerol in the panel of diagnostic tests for fetal lung maturity.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.