Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 30: 1552-1554, 1984;
This Article
Right arrow Full Text (PDF)
Right arrow A correction has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Leroux, M. L.
Right arrow Articles by Desjardins, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Leroux, M. L.
Right arrow Articles by Desjardins, P. R.

Clinical Chemistry, Vol 30, 1552-1554, Copyright © 1984 by American Association for Clinical Chemistry

Clinical effectiveness of the Du Pont aca measurement of creatine kinase MB in serum from patients in a coronary-care unit

ML Leroux, J Rabson and PR Desjardins

We evaluated the clinical effectiveness of measuring creatine kinase (CK; EC 2.7.3.2) isoenzyme MB and lactate dehydrogenase (LD; EC 1.1.1.27) isoenzymes in diagnosis of acute myocardial infarction. We used an agarose electrophoresis method to measure CK and LD isoenzymes and the Du Pont aca column method to measure CK-MB. Serial blood specimens were drawn from 100 patients consecutively admitted to our Coronary Care Unit. Because of the low diagnostic specificity for CK-MB measurements by both agarose electrophoresis and the discrete-analysis method, as compared with reported values, we re-evaluated our isoenzyme data by using Receiver Operating Characteristic curves. Such analysis of the data established optimal decision levels of greater than or equal to 25 U/L and greater than or equal to 18 U/L plus greater than or equal to 6% of total CK for serum CK-MB measured by the agarose electrophoresis and the aca methods, respectively, and an optimal decision level of greater than or equal to 0.92 for the ratio of LD 1/2 measured after agarose electrophoresis. At these decision levels we obtained a sensitivity of 100%, 100%, and 95% and a specificity of 94%, 92%, and 90% for CK-MB (agarose electrophoresis), CK-MB (aca), and the LD 1/2 ratio, respectively.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1984 by the American Association for Clinical Chemistry.