Clinical Chemistry
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 114-117, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fluckiger, R.
Right arrow Articles by Woodtli, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fluckiger, R.
Right arrow Articles by Woodtli, T.

Clinical Chemistry, Vol 31, 114-117, Copyright © 1985 by American Association for Clinical Chemistry

Effect of temperature on quantifying glycated (glycosylated) hemoglobin by cation-exchange chromatography

R Fluckiger and T Woodtli

As a consequence of nonideal chromatographic conditions, values for stable glycated hemoglobin (HbA1c) determined by cation-exchange chromatography in a commercial minicolumn system (y) or by "high- performance" liquid chromatography (x) differ markedly, yielding the regression line y = 0.82x + 0.6. With use of the protocol specified by the manufacturer, 20% of the HbA1c peak is not collected in the HbA1c fraction. Increasing the ionic strength of the eluting buffer by increasing the operating temperature to 28 degrees C increases the rate of elution from the minicolumn, making results of the two methods more closely comparable (y = 0.98x - 0.22). Because at a given pH the elution volume is determined primarily by the ionic strength, close limits on the composition of the eluting buffer are set by the temperature-dependence of its ionic strength. At a specified temperature and pH the position of a peak can be judged to within a volume of 1 mL if the conductivity of the eluent does not vary by more than +/- 0.05 mS.


The following articles in journals at HighWire Press have cited this article:


Home page
Clin. Chem.Home page
W. Hoelzel, C. Weykamp, J.-O. Jeppsson, K. Miedema, J. R. Barr, I. Goodall, T. Hoshino, W. G. John, U. Kobold, R. Little, et al.
IFCC Reference System for Measurement of Hemoglobin A1c in Human Blood and the National Standardization Schemes in the United States, Japan, and Sweden: A Method-Comparison Study
Clin. Chem., January 1, 2004; 50(1): 166 - 174.
[Abstract] [Full Text] [PDF]


Home page
Clin. Chem.Home page
U. Kobold, J.-O. Jeppsson, T. Dulffer, A. Finke, W. Hoelzel, and K. Miedema
Candidate reference methods for hemoglobin A1c based on peptide mapping
Clin. Chem., October 1, 1997; 43(10): 1944 - 1951.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.