Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 41-45, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pollet, D. E.
Right arrow Articles by De Broe, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pollet, D. E.
Right arrow Articles by De Broe, M. E.

Clinical Chemistry, Vol 31, 41-45, Copyright © 1985 by American Association for Clinical Chemistry

Enzyme-antigen immunoassay for human placental alkaline phosphatase in serum and tissue extracts, and its application as a tumor marker

DE Pollet, EJ Nouwen, JB Schelstraete, J Renard, A Van de Voorde and ME De Broe

In this enzyme-antigen immunoassay for human placental alkaline phosphatase (hPLAP; EC 3.1.3.1.) in serum and tissue extracts, polyclonal rabbit antiserum to mouse IgG2b is adsorbed to the wells of a microtiter plate, its excess binding sites are blocked, then it is incubated with murine monoclonal anti-hPLAP and mixed with serially diluted standard or sample antigen. The amount of antigen bound is determined by measuring its enzymic activity. The standard curve is linear for hPLAP concentrations of 0.2 to 1 U/L. The mean within-assay CV was 3.8% (SD 0.9%) for a serum sample and 6.1% (SD 3.0%) for a tissue extract. The respective mean between-assay CVs were: 6.7% (SD 2.0%), and 7.0% (SD 2.0%). Serum hPLAP concentrations, determined in four different dilutions, had a CV of 5.5%. We evaluated the method by standard additions and by comparing dilution curves for purified hPLAP, hPLAP in serum, and hPLAP in tissue extracts. The upper limit of activity in normal subjects was 0.1 U/L for serum samples, and 1.0 mU/g wet weight of tissue for tissue extracts. hPLAP activity was increased in 9.8% of all cancer patients, and in 40% of ovarian cancer patients. Almost half of the tumor biopsies were positive for hPLAP activity, and 94% of the biopsies from ovarian neoplasia had an increased activity of this isoenzyme. Of the nonmalignant tissues examined, normal lung tissue had the highest hPLAP activity.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.