Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1611-1615, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wimberley, P. D.
Right arrow Articles by Siggaard-Andersen, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wimberley, P. D.
Right arrow Articles by Siggaard-Andersen, O.

Clinical Chemistry, Vol 31, 1611-1615, Copyright © 1985 by American Association for Clinical Chemistry

Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults

PD Wimberley, K Gronlund Pedersen, J Olsson and O Siggaard-Andersen

Transcutaneous carbon dioxide tension (tc-pco2) at 37, 39, 41, 43, and 45 degrees C, and transcutaneous oxygen tension (tc-po2) at 41, 43, and 45 degrees C were measured simultaneously in 10 healthy adults during hyperventilation and inhalation of O2/CO2 gas. Nine electrodes were applied to each subject: Five CO2 electrodes, one O2 electrode, and three combined O2/CO2 electrodes. The CO2 electrodes had negligible temperature coefficients in the calibration gases, but the O2 electrodes showed an increase in po2 of 4.5% per degree C. With skin application, tc-pco2 increased approximately 4% per degrees C between 37 and 45 degrees C, which is close to the anaerobic temperature coefficient of pco2 in blood. The tc-po2 increases on the skin with increasing temperature appeared to be more dependent on changes in blood flow in skin, but in the temperature range 43 to 45 degrees C, tc- po2 showed the expected decrease in the temperature coefficient with increasing po2. The correlation between transcutaneous and capillary pco2 was close at all transcutaneous electrode temperatures, even 37 degrees C, provided the skin was preheated (via the electrode) to 45 degrees C. For tc-po2, an electrode temperature of at least 43 degrees C was necessary to produce a reasonable correlation between tc-po2 and capillary po2. The combined O2/CO2 electrodes measured slightly higher pco2 values than the single CO2 electrodes, but there were no differences in po2 readings, stabilization time, imprecision, or electrode drift between the two electrode types. The imprecision (CV, %) of tc-pco2 and tc-po2 measurements was approximately twice that of the corresponding capillary blood-gas measurements.


The following articles in journals at HighWire Press have cited this article:


Home page
Anesth. Analg.Home page
P. Eberhard
The Design, Use, and Results of Transcutaneous Carbon Dioxide Analysis: Current and Future Directions
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S48 - S52.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.