Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1698-1702, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Andreolini, F.
Right arrow Articles by Improta, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Andreolini, F.
Right arrow Articles by Improta, F.

Clinical Chemistry, Vol 31, 1698-1702, Copyright © 1985 by American Association for Clinical Chemistry

Estriol and its conjugates in late pregnancy determined by extraction with Carbopack B and liquid chromatography with fluorometric detection

F Andreolini, C Borra, F Caccamo, A Di Corcia, I Nicoletti, R Samperi and F Improta

We report a method for measuring estriol and its intact conjugates in urine, serum, and amniotic fluid. A single assay can be done within about 50 min, eight samples assayed in less than 5 h. A 70-microL urine sample is diluted and the estriol conjugates are adsorbed from it onto graphitized carbon black (Carbopack B, Supelco). After two washings, the analytes are desorbed with chloroform/methanol (60/40, by vol) containing tetrapropylammonium bromide. After solvent evaporation, the residue is redissolved in 100 microL of water/acetonitrile and 20 microL is injected into the chromatograph. Or 1 mL of serum or 0.5 mL of amniotic fluid is deproteinized with cold methanol, then passed through the Carbopack column. After three washings, the estriol and its conjugates are desorbed and treated as for urine. Mean analytical recoveries of the analytes in any of these body fluids were within about 92-98%, except for estriol-3-sulfate-16 alpha-glucuronide in serum (mean recovery 88.3%). The limit of sensitivity is well below the concentrations of clinical interest, and the method is not susceptible to substantial interferences.