Clinical Chemistry AACC Online Job Center
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 1806-1810, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pudek, M. R.
Right arrow Articles by Humphries, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pudek, M. R.
Right arrow Articles by Humphries, K.

Clinical Chemistry, Vol 31, 1806-1810, Copyright © 1985 by American Association for Clinical Chemistry

Effect of assay conditions on cross reactivity of digoxin-like immunoreactive substance(s) with radioimmunoassay kits

MR Pudek, DW Seccombe, BE Jacobson and K Humphries

One or more digoxin-like immunoreactive substances (DLIS), most frequently present in serum of premature and full-term neonates. cross react to various extents with different digoxin immunoassay kit reagents. Mostly, this variation is attributed to the relative cross reactivity of DLIS with the antiserum in each kit. However, modification of standard assay procedures for digoxin can also greatly alter the relative cross reactivity of DLIS. Using sequential RIA kit methods for digoxin by 20 to 60% relative to the standard equilibrium RIA mode. Cross reactivity was decreased still more if the concentrations of antiserum (binding-site concentration) and tracer (125 l-labeled digoxin) were decreased, and conversely. Serum samples containing only digoxin, analyzed by the modified method, consistently yielded results well comparable with those obtained with the manufacturers' recommended procedures. We describe use of the different responses to digoxin and DLIS of standard and sequential radioimmunoassays and use of simultaneous equation to calculate the concentration of DLIS (in digoxin equivalents) in digoxin-containing samples.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.