Clinical Chemistry Link to Randox Laboratories Web Site
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Clinical Chemistry 31: 2024-2027, 1985;
This Article
Right arrow Full Text (PDF)
Right arrow Submit an electronic Letter to
the Editor about this paper
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Feldkamp, C. S.
Right arrow Articles by Amin, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Feldkamp, C. S.
Right arrow Articles by Amin, V.

Clinical Chemistry, Vol 31, 2024-2027, Copyright © 1985 by American Association for Clinical Chemistry

Anti-IgG combined with rate nephelometry for measuring polyethylene glycol-precipitated circulating immune complexes

CS Feldkamp, SS Levinson, M Perry and V Amin

Immune complexes from serum were assayed for IgG by a simple rate- nephelometric method after extraction with polyethylene glycol that removes monomeric IgG. A 30-min preincubation of the extracted material in reaction buffer before the anti-IgG is introduced eliminates falsely increased values owing to precipitation that increased baseline light scatter in the reaction buffer. We found good parallelism in the reaction of anti-IgG with the IgG calibrator, aggregated human globulin, or endogenous immune complex. Thus IgG can be used for calibration in place of aggregated human globulin, greatly simplifying the assay. A good correlation was found between the present assay and the C1q-binding test (r = 0.83). The present assay is both sensitive and reproducible. The extraction and assay are straightforward and can be completed in a single morning after an overnight precipitation. The reagents for extraction are easily prepared and inexpensive, and the materials for assay are available in kit form. We believe this approach to be well suited for many clinical laboratories to measure circulating immune complexes.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1985 by the American Association for Clinical Chemistry.